Dean RWA Series

Dean Pumps · RWA Series

Dean RWA pumps and repair kits

Dean RWA is an air-cooled centrifugal pump for hot water, ethylene glycol, propylene glycol, and triethylene glycol. A shaft-mounted fan across a finned bearing frame cools the bearings and seal chamber. No cooling-water jacket.

Series ratings: 1,100 GPM, 425 ft, 400 °F (205 °C), 450 psig, ductile iron, 13 sizes. Hot water and glycols only. Heat transfer oil uses Dean RA. See RA vs RWA selection and the RA Series page.

Built in Indianapolis at 6040 Guion Road. Complete pumps are built to order.

Dean is a Tusk Industrial brand. Listed RWA repair kits ship in 24–48 h.

Dean RWA air-cooled pump for hot water and glycol
  • 1,100 GPMCapacity
  • 425 ftHead
  • 400 °FTemperature
  • 450 psigPressure

RWA2096, RWA4166, RWA4206

We sell three frames: RWA2096, RWA4166, and RWA4206. Maximum temperature 400 °F (RWA2096: 320 °F at 210 psig). Seal faces use silicon carbide vs carbon with Aflas elastomers. An air vapor eliminator vents vapor from the seal chamber. Match series to fluid before ordering parts.

  RWA2096 RWA4166 RWA4206
Price $9,727 $12,458 $33,409
Lead time Call Call Call
Service Hot water / glycol Hot water / glycol Hot water / glycol
Max temperature 320 °F (210 psig) 400 °F 400 °F
Seal elastomers Aflas Aflas Aflas
Seal auxiliary Air vapor eliminator Air vapor eliminator Air vapor eliminator
Repair kit 6138159 (8 in)6 in sizes: Call 6138162 (8.5 in)
6138163 (10 in)
6138183 (4x6x10 #1)

Listed prices are bare-pump starting points on this site. Impeller trim, baseplate, motor, coupling, and rebalance change the total. Call 888-341-7085 or sales@pumpresource.us.

Selection

  • Use RWA for hot water, EG, PG, or TEG. Use RA for heat transfer oil.
  • Both RA and RWA are air-cooled. Series choice follows seal materials, elastomers, and auxiliaries for the fluid.
  • Confirm size/model and actual impeller diameter before ordering a kit. OEM heater builders often trim a full-size impeller and may not restamp the tag. See the nameplate guide.
  • 13 factory sizes in the series. Additional sizes are quoted.

Repair kits

Rotating-element kits cover the wear parts for a rebuild. Individual parts: Dean Pump Parts.

Kit SKU Fits Price Ship
RWA2096 8" 6138159 RWA2096 1x1.5x8 only $6,405.56 24–48 h
RWA2096 6" — RWA2096 1x1.5x6, 1.5x3x6 (no kit listed) Call Call
RWA4166 8.5" 6138162 RWA4166 1x3, 1.5x3, 2x3, 3x4, 4x6 × 8.5 $7,915.00 24–48 h
RWA4166 10" 6138163 RWA4166 1.5x3, 2x3, 3x4, 4x6x10 #2 $7,984.00 24–48 h
RWA4206 4x6x10 #1 6138183 RWA4206 4x6x10 #1 only (the only RWA4206 size) $15,596.00 24–48 h

Match kit to impeller diameter and frame. On 4x6x10, match #1 (RWA4206) vs #2 (RWA4166); kits do not interchange. If the kit for your size is not listed, call with the nameplate photo.

Lead time

Complete pumps are built to order. Confirm current stock and lead time before you order. 888-341-7085 · sales@pumpresource.us · Contact.

RWA vs RA

RWA: hot water, ethylene glycol, propylene glycol, triethylene glycol. 400 °F (205 °C), 1,100 GPM, 450 psig, 13 sizes. Aflas seal package and air vapor eliminator.

RA: heat transfer oil. 650 °F (343 °C), 6,000 GPM, 350 psig, 27 sizes. Viton seal package and barrier-fluid cavity. Dean RA Series.

For questions, feel free to call 888-341-7085 or email sales@pumpresource.us.